Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Calibrator
  • 081318501594 VICTOR VC-04 V/ mA Calibrator murah di Jakarta Indonesia/ VICTOR 04 V/ mA Calibrator Handheld Autoranging Electronic Instrument with 5-digit Large LCD Display.Ana 081318501594 email: suksesmakmur65@ yahoo.com

081318501594 VICTOR VC-04 V/ mA Calibrator murah di Jakarta Indonesia/ VICTOR 04 V/ mA Calibrator Handheld Autoranging Electronic Instrument with 5-digit Large LCD Display.Ana 081318501594 email: suksesmakmur65@ yahoo.com

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Lusin
Dilihat Sebanyak
:
35 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail 081318501594 VICTOR VC-04 V/ MA Calibrator Murah Di Jakarta Indonesia/ VICTOR 04 V/ MA Calibrator Handheld Autoranging Electronic Instrument With 5-digit Large LCD Display.Ana 081318501594 Email: Suksesmakmur65@ Yahoo.com

VICTOR VC-04 V/ mA Calibrator Handheld Autoranging Electronic Instrument with 5-digit Large LCD Display Product Description Features: DCV, DCA signal output Can provide 24V circuit power supply mA and percentage display 5-digit large LCD display Easy to operate SKU: X1IN10140 Note: 1.The max.overlaod is 1k¦ ¸ at 20mA range when the power is higher than 6.8V. 2.The max.overlaod is 700¦ ¸ at 20mA range when the power is higher than 5.8 to 6.8V. 3.Temperature coefficient: ¡ À 0.005% , range/ Centigrade ( 5 to 28 Centigrade, 18 to 40 Centigrade) Package Includes: 1 * VICTOR 04 Thermocouple Calibrator VICTOR 04 V/ mA Calibrator Input Range Input range Resolution Accuracy Explanation Voltage 10V 0.000 ~ 11.000V 1mV ± 0.05% Setting value ± 2mV The max.output current is 10mA Current 20mA 0.000~ 22.000mA 0.001mA ± 0.05% Setting value ± 4uA 20mA, the max.overload is 1k© ( Note1) Analogue transducer( absorption) -20mA 0.000~ -22.000mA 0.001mA ± 0.1% Setting value ± 4uA 20mA, the max.overload is 1k© Loop power 24V ± 10% The max.output current is 25mA Power 9V battery ( ANSI/ NEDA 1640A or IEC 6LR619 alkaline) or AC power adapter Battery Approx. 20 hours under the condition of 10mA Max.allowable voltage 30V Operation temperture range 0-50° C Operation humidity range d80% RH Store temperature range d-10° C-50° C Store humidity range d90% RH Size 200× 100× 40mm Weight 550g( with holster) Accessories Operation manual, test line CF-36( probe with alligator clip) Options AC adapter( VCPS) , test line CF-31-A( probe clip) Security Conforms to IEC 1010 Note: 1.The max.overlaod is 1k© at 20mA range when the power is higher than 6.8V, The max.overlaod is 700© at 20mA range when the power is higher than 5.8-6.8V, 2.Temperature coefficient: ± 0.005% , range/ ° C( 5° C-28° C, 18° C-40° C)
Tampilkan Lebih Banyak